Floorplan Studio
IDC1 · Datahall 1
IDC2 · Datahall 2
IDC3 · Datahall 3
IDC4 · Datahall 4
IDC5 · Datahall 5
REV 01
2D
3D
CAD Hell
de
en
Mock-Connector
Gespeichert
Keine Auswahl
CAD
Power A/B
Kapazität HE
0°
Innen
Achse
Aus
Achsen vorn
65%
A
A
B
B
C
C
D
D
E
E
F
F
G
G
H
H
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
4'800
900
2'700
900
14'100
900
2'700
900
4'800
14'700
29'100
14'700
CAGE OST · KUNDE CORVU
WARMGANG 01
KALTGANG 01
32 × LOCHPLATTE 25 %
WARMGANG 02
KALTGANG 02
32 × LOCHPLATTE 25 %
WARMGANG 03
KALTGANG 03
24 × LOCHPLATTE 25 %
WARMGANG 04
KALTGANG 04
22 × LOCHPLATTE 25 %
KALTGANG 04
1 × LOCHPLATTE 25 %
KALTGANG 04
0 × LOCHPLATTE 25 %
WARMGANG 05
KALTGANG 05
32 × LOCHPLATTE 25 %
WARMGANG 06
WARMGANG 06
KALTGANG 06
32 × LOCHPLATTE 25 %
WARMGANG 07
KALTGANG 07
32 × LOCHPLATTE 25 %
T01 · EI60 · 1000+500
T02 · EI60 · 1000+500
01.01
01.02
01.03
01.04
01.05
01.06
01.07
01.08
01.09
01.10
01.11
01.12
01.13
01.14
01.15
01.16
02.01
02.02
02.03
02.05
02.06
02.07
02.08
02.09
02.10
02.11
02.13
02.14
02.15
02.16
03.01
03.02
03.03
03.04
03.05
03.06
03.07
03.08
03.09
03.10
03.11
03.12
03.13
03.14
03.15
03.16
04.01
04.02
04.03
04.05
04.06
04.07
04.08
04.09
04.10
04.11
04.13
04.14
04.15
04.16
05.05
05.06
05.07
05.08
05.09
05.10
05.11
05.12
05.13
05.14
05.15
05.16
06.05
06.06
06.07
06.08
06.09
06.10
06.11
06.13
06.14
06.15
06.16
07.05
07.06
07.07
07.08
07.09
07.10
07.11
08.01
08.02
08.03
08.05
08.06
08.07
08.08
08.09
08.10
08.11
09.01
09.02
09.03
09.04
09.05
09.06
09.07
09.08
09.09
09.10
09.11
09.12
09.13
09.14
09.15
09.16
10.01
10.02
10.03
10.15
10.16
11.01
11.02
11.03
11.04
11.05
11.06
11.07
11.08
11.09
11.15
11.16
12.01
12.02
12.03
12.05
12.06
12.07
12.08
12.09
12.10
12.11
12.13
12.14
12.15
12.16
13.01
13.02
13.03
13.04
13.05
13.06
13.07
13.08
13.09
13.10
13.11
13.12
13.13
13.14
13.15
13.16
SERVICE 900
EOS OST
18.4 kW
SERVICE 900
DC 01
62.8 kW
S1.1
S1.2
S1.3
S1.4
S1.5
S1.6
S2.1
S2.2
S2.3
S2.4
S2.6
LADEZONE 1200
LIFT
SERVICE 900
CRAH 01
DOWNFLOW · 100 kW · 20°C
SERVICE 900
CRAH 02
DOWNFLOW · 100 kW · 20°C
SERVICE 900
CRAH 03
DOWNFLOW · 100 kW · 20°C
SERVICE 900
CRAH 04
DOWNFLOW · 100 kW · 20°C
SERVICE 900
CRAH 05
DOWNFLOW · 100 kW · 20°C
SERVICE 900
CRAH 06
DOWNFLOW · 100 kW · 20°C
SERVICE 900
F1
F2
PDU 1A
150 kVA · 2 Felder
SERVICE 900
A
B
STS 1A
400 A · A/B
SERVICE 900
A
B
STS 1B
400 A · A/B
SERVICE 900
F1
F2
PDU 1B
150 kVA · 2 Felder
SERVICE 900
F1
F2
PDU 2A
150 kVA · 2 Felder
SERVICE 900
A
B
STS 2A
400 A · A/B
SERVICE 900
A
B
STS 2B
400 A · A/B
SERVICE 900
F1
F2
PDU 2B
150 kVA · 2 Felder
SERVICE 900
BAT 01
48 V · 60 min
IDC4
Datahall 4 ·
437 m² · 162 Racks
0.0
kW